Inspection Type |
Referral
|
Scope |
Partial
|
Safety/Health |
Health
|
Close Conference |
2016-01-21
|
Emphasis |
N: DUSTEXPL
|
Case Closed |
2018-08-06
|
Related Activity
Type |
Inspection |
Activity Nr |
1118435 |
Safety |
Yes |
|
Type |
Inspection |
Activity Nr |
1118761 |
Health |
Yes |
|
Type |
Referral |
Activity Nr |
1054768 |
Health |
Yes |
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19100022 A01 |
Issuance Date |
2016-07-01 |
Abatement Due Date |
2016-07-06 |
Current Penalty |
1680.0 |
Initial Penalty |
2800.0 |
Final Order |
2016-08-02 |
Nr Instances |
1 |
Nr Exposed |
15 |
Related Event Code (REC) |
Referral |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.22(a)(1): All places of employment, passageways, storerooms or service rooms were not kept clean and orderly or in a sanitary condition. (a) On or about 1/21/2016, at work site at 184-60 Jamaica Avenue, Jamaica, NY 11423 Housekeeping practices were inadequate to prevent accumulation of combustible wood dust in the woodworking room. At least 7% of the room, including floor, shelves, window sills, window caulking, light fixtures and other horizontal surfaces were covered in wood dust at a depth of greater than 1/32 inch. ABATEMENT DOCUMENTATION REQUIRED PURSUANT TO 29 CFR 1903.19. |
|
Citation ID |
01002A |
Citaton Type |
Other |
Standard Cited |
19100134 C01 |
Issuance Date |
2016-07-01 |
Abatement Due Date |
2016-08-16 |
Current Penalty |
0.0 |
Initial Penalty |
1200.0 |
Final Order |
2016-08-02 |
Nr Instances |
1 |
Nr Exposed |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.134(c)(1): A written respiratory protection program that included the provisions in 29 CFR 1910.134(c)(1)(i) - (ix) with worksite specific procedures was not established and implemented for required respirator use: (a) On or about 5/4/2016, at work site at 184-60 Jamaica Avenue, Jamaica, NY 11423 Employer had not established a written respiratory protection program where an employee who performs woodworking tasks was required to wear N95 respirators. ABATEMENT CERTIFICATION REQUIRED PURUANT TO 29 CFR 1903.19 |
|
Citation ID |
01002B |
Citaton Type |
Serious |
Standard Cited |
19100134 E01 |
Issuance Date |
2016-07-01 |
Abatement Due Date |
2016-08-16 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2016-08-02 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.134(e)(1): The employer did not provide a medical evaluation to determine the employee's ability to use a respirator, before the employee was fit tested or required to use the respirator in the workplace: (a) On or about 5/4/2016, at work site at 184-60 Jamaica Avenue, Jamaica, NY 11423 Employees who are required to wear N95 respirators when performing woodworking tasks did not receive medical evaluation prior to using the respirator. ABATEMENT CERTIFICATION REQUIRED PURUANT TO 29 CFR 1903.19 |
|
Citation ID |
01002C |
Citaton Type |
Serious |
Standard Cited |
19100134 F01 |
Issuance Date |
2016-07-01 |
Abatement Due Date |
2016-08-16 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2016-08-02 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.134(f)(1): The employer did not ensure that employee(s) required to use a tight-fitting facepiece respirator passed the appropriate qualitative fit test (QLFT) or quantitative fit test (QNFT): (a) On or about 5/4/2016, at work site at 184-60 Jamaica Avenue, Jamaica, NY 11423 Employer did not have employees who are required to wear tight-fitting N95 respirators while performing woodworking tasks fit tested. ABATEMENT CERTIFICATION REQUIRED PURUANT TO 29 CFR 1903.19 |
|
Citation ID |
01002D |
Citaton Type |
Serious |
Standard Cited |
19100134 K |
Issuance Date |
2016-07-01 |
Abatement Due Date |
2016-08-16 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2016-08-02 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.134(k): The employer did not provide comprehensive, understandable, and effective annual training to employees who were required to use respirators. (a) On or about 5/4/2016, at work site at 184-60 Jamaica Avenue, Jamaica, NY 11423 Employer did not provide respirator training to employees who are required to wear N95 respirators while performing woodworking tasks. ABATEMENT CERTIFICATION REQUIRED PURUANT TO 29 CFR 1903.19. |
|
Citation ID |
01003A |
Citaton Type |
Serious |
Standard Cited |
19100305 B01 II |
Issuance Date |
2016-07-01 |
Abatement Due Date |
2016-07-06 |
Current Penalty |
720.0 |
Initial Penalty |
1200.0 |
Final Order |
2016-08-02 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.305(b)(1)(ii): Unused openings in boxes, cabinets, or fittings were not effectively closed: (a) On or about 1/21/2016, at work site at 184-60 Jamaica Avenue, Jamaica, NY 11423 Unused openings in at least four ceiling-mounted electrical boxes were not closed, allowing possible accumulation of fine, combustible wood dust inside the boxes. ABATEMENT CERTIFICATION IS REQUIRED PURSUANT TO 29 CFR 1903.19. |
|
Citation ID |
01003B |
Citaton Type |
Serious |
Standard Cited |
19100305 G01 IV A |
Issuance Date |
2016-07-01 |
Abatement Due Date |
2016-07-06 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2016-08-02 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.305(g)(1)(iv)(A): Flexible cords and/or cables were used as a substitute for the fixed wiring of a structure: (a) On or about 5/4/2016, at work site at 184-60 Jamaica Avenue, Jamaica, NY 11423 A window-mounted fan in the woodworking room which is used daily had a power cord which had been spliced to a separate flexible cord to add length, instead of using the original cord alone to connect to a more closely located fixed outlet. ABATEMENT CERTIFICATION IS REQUIRED PURSUANT TO 29 CFR 1903.19. |
|
Citation ID |
01003C |
Citaton Type |
Serious |
Standard Cited |
19100305 G02 II |
Issuance Date |
2016-07-01 |
Abatement Due Date |
2016-07-06 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2016-08-02 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.305(g)(2)(ii): Flexible cords were not used only in continuous lengths without splice or tap: (a) On or about 5/4/2016, at work site at 184-60 Jamaica Avenue, Jamaica, NY 11423 A window-mounted fan in the woodworking room which is used daily had its power cord spliced to a separate flexible cord to add length. Splices were joined with wire connectors which were not covered. ABATEMENT CERTIFICATION REQUIRED PURSUANT TO 29 CFR 1903.19. |
|
Citation ID |
02001 |
Citaton Type |
Other |
Standard Cited |
19100157 C01 |
Issuance Date |
2016-07-01 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2016-08-02 |
Nr Instances |
1 |
Nr Exposed |
15 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.157(c)(1): Portable fire extinguishers were not mounted, located and identified so that they were readily accessible without subjecting the employees to injuries: (a) On or about 5/4/2016, at work site at 184-60 Jamaica Avenue, Jamaica, NY 11423 Access to the fire extinguisher in the woodworking room was blocked by stored stacks of wooden trays stored directly in front of the extinguisher. ABATEMENT CERTIFICATION REQUIRED PURSUANT TO 29 CFR 1903.19. |
|
Citation ID |
02002 |
Citaton Type |
Other |
Standard Cited |
19100305 G02 III |
Issuance Date |
2016-07-01 |
Abatement Due Date |
2016-07-06 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2016-08-02 |
Nr Instances |
1 |
Nr Exposed |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.305(g)(2)(iii): Flexible cords and cables were not connected to devices and fittings so that strain relief was provided that would prevent pull from being directly transmitted to joints or terminal screws: (a) On or about 5/4/2016, at work site at 184-60 Jamaica Avenue, Jamaica, NY 11423 Employer did not ensure that strain relief was provided to prevent damage to the power cable of a Central Machinery #39955 20" drill press. ABATEMENT CERTIFICATION REQUIRED PURSUANT TO 29 CFR 1903.19. |
|
|
Inspection Type |
Complaint
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2016-06-30
|
Emphasis |
N: AMPUTATE, N: DUSTEXPL
|
Case Closed |
2024-09-30
|
Related Activity
Type |
Complaint |
Activity Nr |
1053035 |
Safety |
Yes |
|
Type |
Inspection |
Activity Nr |
1119357 |
Health |
Yes |
|
Type |
Inspection |
Activity Nr |
1118761 |
Health |
Yes |
|
Violation Items
Citation ID |
01001A |
Citaton Type |
Serious |
Standard Cited |
19100036 D01 |
Issuance Date |
2016-07-01 |
Abatement Due Date |
2016-07-08 |
Current Penalty |
1200.0 |
Initial Penalty |
2000.0 |
Final Order |
2016-08-02 |
Nr Instances |
1 |
Nr Exposed |
17 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.36(d)(1): Employee(s) were not able to open an exit route door from the inside at all times without keys, tools, or special knowledge: A.) On or about Friday, January 15, 2016 at 184-60 Jamaica Avenue, Hollis, NY 11423 (3rd Floor) An emergency exit door was observed locked with a metal pin and latch preventing prompt egress of employees from the building in the event of a fire and/or other emergency. ABATEMENT CERTIFICATION IS REQUIRED PURSUANT TO 29 CFR 1903.19 |
|
Citation ID |
01001B |
Citaton Type |
Serious |
Standard Cited |
19100037 A04 |
Issuance Date |
2016-07-01 |
Abatement Due Date |
2016-07-14 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2016-08-02 |
Nr Instances |
1 |
Nr Exposed |
18 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.37(a)(4): Safeguard(s) designed to protect employees during an emergency (e.g., sprinkler systems, alarm systems, fire doors, exit lighting), were not in proper working order at all times: A.) On or about Friday, January 15, 2016 at 184-60 Jamaica Avenue, Hollis, NY 11423 (3rd Floor) The bulbs of an emergency exit sign on the 3rd floor of the building next to the woodshop area were not functional. ABATEMENT CERTIFICATION IS REQUIRED PURSUANT TO 29 CFR 1903.19 |
|
Citation ID |
01002A |
Citaton Type |
Other |
Standard Cited |
19100132 D01 |
Issuance Date |
2016-07-01 |
Abatement Due Date |
2016-08-18 |
Current Penalty |
0.0 |
Initial Penalty |
2000.0 |
Final Order |
2016-08-02 |
Nr Instances |
1 |
Nr Exposed |
18 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.132(d)(1): The employer did not assess the workplace to determine if hazards are present, or are likely to be present, which necessitate the use of personal protective equipment (PPE): A.) On or about Friday, January 15, 2016 at 184-60 Jamaica Avenue, Hollis, NY 11423 The employer failed to assess the workplace to determine hazards present necessitating the usage of personal protective equipment (i.e. hand protection) exposing employees to thermal hazards. ABATEMENT CERTIFICATION IS REQUIRED PURSUANT TO 29 CFR 1903.19 |
|
Citation ID |
01002B |
Citaton Type |
Other |
Standard Cited |
19100138 A |
Issuance Date |
2016-07-01 |
Abatement Due Date |
2016-07-21 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2016-08-02 |
Nr Instances |
1 |
Nr Exposed |
3 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.138(a): The employer did not select and require employee(s) to use appropriate hand protection when employees' hands were exposed to hazards such as those from skin absorption of harmful substances; severe cuts or lacerations; severe abrasion; punctures; chemical burns; thermal burns; and harmful temperature extremes. A.) On or about Friday, January 15, 2016 at 184-60 Jamaica Avenue, Hollis, NY 11423 The employer failed to provide employees exposed to thermal burns during the application of clothmaterial to wooden jewelry display cases appropriate hand protection. ABATEMENT CERTIFICATION IS REQUIRED PURSUANT TO 29 CFR 1903.19 |
|
Citation ID |
01003 |
Citaton Type |
Serious |
Standard Cited |
19100212 A03 II |
Issuance Date |
2016-07-01 |
Abatement Due Date |
2016-07-08 |
Current Penalty |
4200.0 |
Initial Penalty |
7000.0 |
Final Order |
2016-08-02 |
Nr Instances |
1 |
Nr Exposed |
3 |
Related Event Code (REC) |
Complaint |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.212(a)(3)(ii): Point(s) of operation of machinery were not guarded to prevent employee(s) from having any part of their body in the danger zone(s) during operating cycle(s): A.) On or about Wednesday, January 6, 2016 at 184-60 Jamaica Avenue, Hollis, NY 11423 The point of operation of a die-cutting machine used during the production of jewelry display cases was observed missing a guard resulting in an employee sustaining injuries to the left hand. B.) On or about Friday, January 15, 2016 at 184-60 Jamaica Avenue, Hollis, NY 11423 The point of operation of a die-cutting machine used during the production of jewelry display cases was observed missing a guard resulting in an employee sustaining injuries to the left hand. ABATEMENT CERTIFICATION IS NOT REQUIRED |
|
Citation ID |
01004 |
Citaton Type |
Serious |
Standard Cited |
19100213 C01 |
Issuance Date |
2016-07-01 |
Abatement Due Date |
2016-07-14 |
Current Penalty |
1600.0 |
Initial Penalty |
2800.0 |
Final Order |
2016-08-02 |
Nr Instances |
1 |
Nr Exposed |
1 |
Related Event Code (REC) |
Complaint |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.213(c)(1): Circular handfed ripsaw(s) were not guarded by an automatically adjusting hood which completely enclosed that portion of the saw above the table and above the material being cut: A.) On or about Friday, January 15, 2016 at 184-60 Jamaica Avenue, Hollis, NY 11423 A table saw used by employees within the woodshop area during the manufacturing of jewelry display cases was observed unguarded exposing employees to amputation hazards. ABATEMENT CERTIFICATION IS REQUIRED PURSUANT TO 29 CFR 1903.19 |
|
Citation ID |
01005A |
Citaton Type |
Serious |
Standard Cited |
19100219 D01 |
Issuance Date |
2016-07-01 |
Abatement Due Date |
2016-08-18 |
Current Penalty |
1200.0 |
Initial Penalty |
2000.0 |
Final Order |
2016-08-02 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.219(d)(1): Pulley(s) with part(s) seven feet or less from the floor or work platform were not guarded in accordance with the requirements specified in 29 CFR 1910.219(m) and (o): A.) On or about Friday, January 15, 2016 at 184-60 Jamaica Avenue, Hollis, NY 11423 (Rear of Building) The vertical pulley of a compressed air tank located in the rear of the building was observed unguarded exposing employees to amputation hazards. ABATEMENT CERTIFICATION IS REQUIRED PURSUANT TO 29 CFR 1903.19 |
|
Citation ID |
01005B |
Citaton Type |
Serious |
Standard Cited |
19100219 E03 I |
Issuance Date |
2016-07-01 |
Abatement Due Date |
2016-08-18 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2016-08-02 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.219(e)(3)(i): Vertical or inclined belt(s) were not enclosed by guard(s) conforming to the requirements specified at 29 CFR 1910.219(m) and (o): A.) On or about Friday, January 15, 2016 at 184-60 Jamaica Avenue, Hollis, NY 11423 (3rd Floor) The belt of a compressed air tank located in the rear of the building was observed missing a guard exposing employees to amputation hazards. ABATEMENT CERTIFICATION IS NOT REQUIRED |
|
Citation ID |
01006 |
Citaton Type |
Serious |
Standard Cited |
19100242 B |
Issuance Date |
2016-07-01 |
Abatement Due Date |
2016-07-28 |
Current Penalty |
1200.0 |
Initial Penalty |
2000.0 |
Final Order |
2016-08-02 |
Nr Instances |
1 |
Nr Exposed |
18 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.242(b): Compressed air used for cleaning purposes was not reduced to less than 30 p.s.i.: A.) On or about Friday, January 15, 2016 at 184-60 Jamaica Avenue, Hollis, NY 11423 Compressed air used by employees for cleaning purpose was not reduced to less than 30 p.s.i. exposing employees to fire/explosion hazards. ABATEMENT CERTIFICATION IS REQUIRED PURSUANT TO 29 CFR 1903.19 |
|
Citation ID |
02001 |
Citaton Type |
Other |
Standard Cited |
19040029 B03 |
Issuance Date |
2016-07-01 |
Abatement Due Date |
2016-07-08 |
Current Penalty |
600.0 |
Initial Penalty |
1000.0 |
Final Order |
2016-08-02 |
Nr Instances |
1 |
Nr Exposed |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1904.29(b)(3): Each recordable injury or illness was not entered on the OSHA 300 Log and on an incident report (OSHA Form 301or equivalent) within seven (7) calendar days of receiving information that a recordable injury or illness had occurred. A.) On or about Friday, January 6, 2016 at 184-60 Jamaica Avenue, Hollis, NY 11423 Within seven (7) calendar days the employer failed to enter a recordable work-related injury involving an employee on the OSHA 300 log for calendar year 2016. ABATEMENT CERTIFICATION IS NOT REQUIRED |
|
Citation ID |
02002 |
Citaton Type |
Other |
Standard Cited |
19040039 A02 |
Issuance Date |
2016-07-01 |
Abatement Due Date |
2016-07-08 |
Current Penalty |
600.0 |
Initial Penalty |
1000.0 |
Final Order |
2016-08-02 |
Nr Instances |
1 |
Nr Exposed |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1904.39(a)(2): The employer did not report an in-patient hospitalization, amputation, or loss of an eye as a result of a work-related incident to OSHA within twenty-four (24) hours. A.) On or about Friday, January 15, 2016 at 184-60 Jamaica Avenue, Hollis, NY 11423 The employer failed to report to OSHA the in-patient hospitalization of employee within twenty-four (24) hours. ABATEMENT CERTIFICATION IS NOT REQUIRED |
|
Citation ID |
02003 |
Citaton Type |
Other |
Standard Cited |
19100147 C07 I C |
Issuance Date |
2016-07-01 |
Abatement Due Date |
2016-08-18 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2016-08-02 |
Nr Instances |
1 |
Nr Exposed |
18 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.147(c)(7)(i)(C): Employees whose work operations were in an area where energy control procedures were utilized were not instructed about the procedure: A.) On or about Friday, January 15, 2016 at 184-60 Jamaica Avenue, Hollis, NY 11423 The employer failed to provide instructions to employees that are required to use and/or work around equipment where energy control procedures are used. ABATEMENT CERIFICATION IS REQUIRED PURSUANT TO 29 CFR 1903.19 |
|
Citation ID |
02004A |
Citaton Type |
Other |
Standard Cited |
19101200 E01 |
Issuance Date |
2016-07-01 |
Abatement Due Date |
2016-08-18 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2016-08-02 |
Nr Instances |
1 |
Nr Exposed |
18 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.1200(e)(1): The employer did not develop, implement, and/or maintain at the workplace a written hazard communication program which describes how the criteria specified in 29 CFR 1910.1200(f), (g), and (h) will be met: A.) On or about Friday, January 15, 2016 at 184-60 Jamaica Avenue, Hollis, NY 11423 The employer failed to develop, implement and maintain a written hazard communication program for employees that are required to use hazardous chemicals such as but not limited too; F90 Flex Glue and R 2258 Resin Adhesive during the fabrication of jewelry display cases. WRITTEN ABATEMENT CERTIFICATION IS REQUIRED PURSUANT TO 29 CFR 1903.19 |
|
Citation ID |
02004B |
Citaton Type |
Other |
Standard Cited |
19101200 F05 I |
Issuance Date |
2016-07-01 |
Abatement Due Date |
2016-07-21 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2016-08-02 |
Nr Instances |
1 |
Nr Exposed |
18 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.1200(f)(5)(i): The employer did not ensure that each container of hazardous chemicals in the workplace was labeled, tagged or marked with the identity of the hazardous chemical(s) contained therein: A.) On or about Friday, January 15, 2016 at 184-60 Jamaica Avenue, Hollis, NY 11423 The employer failed to ensure chemical containers used by employees during the manufacturing of jewelry display cases were properly labeled with the identity of the hazardous chemical. ABATEMENT CERTIFICATION IS REQUIRED PURSUANT TO 29 CFR 1903.19 |
|
Citation ID |
02004C |
Citaton Type |
Other |
Standard Cited |
19101200 H01 |
Issuance Date |
2016-07-01 |
Abatement Due Date |
2016-08-18 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2016-08-02 |
Nr Instances |
1 |
Nr Exposed |
18 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.1200(h)(1): Employees were not provided effective information and training on hazardous chemicals in their work area at the time of their initial assignment and whenever a new hazard that the employees had not been previously trained about was introduced into their work area: A.) On or about Friday, January 15, 2016 at 184-60 Jamaica Avenue, Hollis, NY 11423 The employer failed to provide employees that are required to use hazardous chemicals such as but not limited too; F 90 Flex Glue and R 2258 Resin Adhesive during the manufacturing of jewelry display cases effective information and training in the safe usage of hazardous chemicals. WRITTEN ABATEMENT CERTIFICATION IS REQUIRED PURSUANT TO 29 CFR 1903.19 |
|
|