Search icon

STYLE-BILT JEWELRY CASE CO., INC.

Company Details

Name: STYLE-BILT JEWELRY CASE CO., INC.
Jurisdiction: New York
Legal type: DOMESTIC BUSINESS CORPORATION
Status: Active
Date of registration: 10 Sep 1984 (41 years ago)
Entity Number: 942205
ZIP code: 11201
County: Kings
Place of Formation: New York
Address: 35 YORK ST, BROOKLYN, NY, United States, 11201

Shares Details

Shares issued 200

Share Par Value 0

Type NO PAR VALUE

DOS Process Agent

Name Role Address
JERRY SILVERSTEIN DOS Process Agent 35 YORK ST, BROOKLYN, NY, United States, 11201

Chief Executive Officer

Name Role Address
JERRY SILVERSTEIN Chief Executive Officer 35 YORK ST, BROOKLYN, NY, United States, 11201

History

Start date End date Type Value
1984-09-10 2022-11-22 Shares Share type: NO PAR VALUE, Number of shares: 200, Par value: 0
1984-09-10 1995-05-12 Address 295 MADISON AVE., NEW YORK, NY, 10017, USA (Type of address: Service of Process)

Filings

Filing Number Date Filed Type Effective Date
980828002403 1998-08-28 BIENNIAL STATEMENT 1998-09-01
960903002186 1996-09-03 BIENNIAL STATEMENT 1996-09-01
950512002014 1995-05-12 BIENNIAL STATEMENT 1993-09-01
B140132-4 1984-09-10 CERTIFICATE OF INCORPORATION 1984-09-10

OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
342220068 0215600 2017-03-27 184-60 JAMAICA AVENUE, HOLLIS, NY, 11423
Inspection Type Complaint
Scope Partial
Safety/Health Safety
Close Conference 2017-09-19
Emphasis N: AMPUTATE
Case Closed 2019-11-19

Related Activity

Type Complaint
Activity Nr 1198300
Safety Yes

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19100213 C01
Issuance Date 2017-09-20
Abatement Due Date 2017-09-26
Current Penalty 3900.0
Initial Penalty 5577.0
Final Order 2017-10-19
Nr Instances 1
Nr Exposed 1
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.213(c)(1): Circular handfed ripsaw(s) were not guarded by an automatically adjusting hood which completely enclosed that portion of the saw above the table and above the material being cut: A.) On or about Tuesday, March 21, 2017 at 184-60 Jamaica Avenue, Hollis, NY 11423 An electric table saw used by employees to cut wooden boards into sections was observed missing a guard. ABATEMENT CERTIFICATION IS REQUIRED PURSUANT TO 29 CFR 1903.19
341193571 0215600 2016-01-21 184-60 JAMAICA AVENUE, JAMAICA, NY, 11423
Inspection Type Referral
Scope Partial
Safety/Health Health
Close Conference 2016-01-21
Emphasis N: DUSTEXPL
Case Closed 2018-08-06

Related Activity

Type Inspection
Activity Nr 1118435
Safety Yes
Type Inspection
Activity Nr 1118761
Health Yes
Type Referral
Activity Nr 1054768
Health Yes

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19100022 A01
Issuance Date 2016-07-01
Abatement Due Date 2016-07-06
Current Penalty 1680.0
Initial Penalty 2800.0
Final Order 2016-08-02
Nr Instances 1
Nr Exposed 15
Related Event Code (REC) Referral
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.22(a)(1): All places of employment, passageways, storerooms or service rooms were not kept clean and orderly or in a sanitary condition. (a) On or about 1/21/2016, at work site at 184-60 Jamaica Avenue, Jamaica, NY 11423 Housekeeping practices were inadequate to prevent accumulation of combustible wood dust in the woodworking room. At least 7% of the room, including floor, shelves, window sills, window caulking, light fixtures and other horizontal surfaces were covered in wood dust at a depth of greater than 1/32 inch. ABATEMENT DOCUMENTATION REQUIRED PURSUANT TO 29 CFR 1903.19.
Citation ID 01002A
Citaton Type Other
Standard Cited 19100134 C01
Issuance Date 2016-07-01
Abatement Due Date 2016-08-16
Current Penalty 0.0
Initial Penalty 1200.0
Final Order 2016-08-02
Nr Instances 1
Nr Exposed 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.134(c)(1): A written respiratory protection program that included the provisions in 29 CFR 1910.134(c)(1)(i) - (ix) with worksite specific procedures was not established and implemented for required respirator use: (a) On or about 5/4/2016, at work site at 184-60 Jamaica Avenue, Jamaica, NY 11423 Employer had not established a written respiratory protection program where an employee who performs woodworking tasks was required to wear N95 respirators. ABATEMENT CERTIFICATION REQUIRED PURUANT TO 29 CFR 1903.19
Citation ID 01002B
Citaton Type Serious
Standard Cited 19100134 E01
Issuance Date 2016-07-01
Abatement Due Date 2016-08-16
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2016-08-02
Nr Instances 1
Nr Exposed 1
Gravity 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.134(e)(1): The employer did not provide a medical evaluation to determine the employee's ability to use a respirator, before the employee was fit tested or required to use the respirator in the workplace: (a) On or about 5/4/2016, at work site at 184-60 Jamaica Avenue, Jamaica, NY 11423 Employees who are required to wear N95 respirators when performing woodworking tasks did not receive medical evaluation prior to using the respirator. ABATEMENT CERTIFICATION REQUIRED PURUANT TO 29 CFR 1903.19
Citation ID 01002C
Citaton Type Serious
Standard Cited 19100134 F01
Issuance Date 2016-07-01
Abatement Due Date 2016-08-16
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2016-08-02
Nr Instances 1
Nr Exposed 1
Gravity 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.134(f)(1): The employer did not ensure that employee(s) required to use a tight-fitting facepiece respirator passed the appropriate qualitative fit test (QLFT) or quantitative fit test (QNFT): (a) On or about 5/4/2016, at work site at 184-60 Jamaica Avenue, Jamaica, NY 11423 Employer did not have employees who are required to wear tight-fitting N95 respirators while performing woodworking tasks fit tested. ABATEMENT CERTIFICATION REQUIRED PURUANT TO 29 CFR 1903.19
Citation ID 01002D
Citaton Type Serious
Standard Cited 19100134 K
Issuance Date 2016-07-01
Abatement Due Date 2016-08-16
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2016-08-02
Nr Instances 1
Nr Exposed 1
Gravity 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.134(k): The employer did not provide comprehensive, understandable, and effective annual training to employees who were required to use respirators. (a) On or about 5/4/2016, at work site at 184-60 Jamaica Avenue, Jamaica, NY 11423 Employer did not provide respirator training to employees who are required to wear N95 respirators while performing woodworking tasks. ABATEMENT CERTIFICATION REQUIRED PURUANT TO 29 CFR 1903.19.
Citation ID 01003A
Citaton Type Serious
Standard Cited 19100305 B01 II
Issuance Date 2016-07-01
Abatement Due Date 2016-07-06
Current Penalty 720.0
Initial Penalty 1200.0
Final Order 2016-08-02
Nr Instances 1
Nr Exposed 1
Gravity 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.305(b)(1)(ii): Unused openings in boxes, cabinets, or fittings were not effectively closed: (a) On or about 1/21/2016, at work site at 184-60 Jamaica Avenue, Jamaica, NY 11423 Unused openings in at least four ceiling-mounted electrical boxes were not closed, allowing possible accumulation of fine, combustible wood dust inside the boxes. ABATEMENT CERTIFICATION IS REQUIRED PURSUANT TO 29 CFR 1903.19.
Citation ID 01003B
Citaton Type Serious
Standard Cited 19100305 G01 IV A
Issuance Date 2016-07-01
Abatement Due Date 2016-07-06
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2016-08-02
Nr Instances 1
Nr Exposed 1
Gravity 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.305(g)(1)(iv)(A): Flexible cords and/or cables were used as a substitute for the fixed wiring of a structure: (a) On or about 5/4/2016, at work site at 184-60 Jamaica Avenue, Jamaica, NY 11423 A window-mounted fan in the woodworking room which is used daily had a power cord which had been spliced to a separate flexible cord to add length, instead of using the original cord alone to connect to a more closely located fixed outlet. ABATEMENT CERTIFICATION IS REQUIRED PURSUANT TO 29 CFR 1903.19.
Citation ID 01003C
Citaton Type Serious
Standard Cited 19100305 G02 II
Issuance Date 2016-07-01
Abatement Due Date 2016-07-06
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2016-08-02
Nr Instances 1
Nr Exposed 1
Gravity 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.305(g)(2)(ii): Flexible cords were not used only in continuous lengths without splice or tap: (a) On or about 5/4/2016, at work site at 184-60 Jamaica Avenue, Jamaica, NY 11423 A window-mounted fan in the woodworking room which is used daily had its power cord spliced to a separate flexible cord to add length. Splices were joined with wire connectors which were not covered. ABATEMENT CERTIFICATION REQUIRED PURSUANT TO 29 CFR 1903.19.
Citation ID 02001
Citaton Type Other
Standard Cited 19100157 C01
Issuance Date 2016-07-01
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2016-08-02
Nr Instances 1
Nr Exposed 15
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.157(c)(1): Portable fire extinguishers were not mounted, located and identified so that they were readily accessible without subjecting the employees to injuries: (a) On or about 5/4/2016, at work site at 184-60 Jamaica Avenue, Jamaica, NY 11423 Access to the fire extinguisher in the woodworking room was blocked by stored stacks of wooden trays stored directly in front of the extinguisher. ABATEMENT CERTIFICATION REQUIRED PURSUANT TO 29 CFR 1903.19.
Citation ID 02002
Citaton Type Other
Standard Cited 19100305 G02 III
Issuance Date 2016-07-01
Abatement Due Date 2016-07-06
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2016-08-02
Nr Instances 1
Nr Exposed 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.305(g)(2)(iii): Flexible cords and cables were not connected to devices and fittings so that strain relief was provided that would prevent pull from being directly transmitted to joints or terminal screws: (a) On or about 5/4/2016, at work site at 184-60 Jamaica Avenue, Jamaica, NY 11423 Employer did not ensure that strain relief was provided to prevent damage to the power cable of a Central Machinery #39955 20" drill press. ABATEMENT CERTIFICATION REQUIRED PURSUANT TO 29 CFR 1903.19.
341184356 0215600 2016-01-15 184-60 JAMAICA AVENUE, JAMAICA, NY, 11423
Inspection Type Complaint
Scope Partial
Safety/Health Safety
Close Conference 2016-06-30
Emphasis N: AMPUTATE, N: DUSTEXPL
Case Closed 2024-09-30

Related Activity

Type Complaint
Activity Nr 1053035
Safety Yes
Type Inspection
Activity Nr 1119357
Health Yes
Type Inspection
Activity Nr 1118761
Health Yes

Violation Items

Citation ID 01001A
Citaton Type Serious
Standard Cited 19100036 D01
Issuance Date 2016-07-01
Abatement Due Date 2016-07-08
Current Penalty 1200.0
Initial Penalty 2000.0
Final Order 2016-08-02
Nr Instances 1
Nr Exposed 17
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.36(d)(1): Employee(s) were not able to open an exit route door from the inside at all times without keys, tools, or special knowledge: A.) On or about Friday, January 15, 2016 at 184-60 Jamaica Avenue, Hollis, NY 11423 (3rd Floor) An emergency exit door was observed locked with a metal pin and latch preventing prompt egress of employees from the building in the event of a fire and/or other emergency. ABATEMENT CERTIFICATION IS REQUIRED PURSUANT TO 29 CFR 1903.19
Citation ID 01001B
Citaton Type Serious
Standard Cited 19100037 A04
Issuance Date 2016-07-01
Abatement Due Date 2016-07-14
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2016-08-02
Nr Instances 1
Nr Exposed 18
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.37(a)(4): Safeguard(s) designed to protect employees during an emergency (e.g., sprinkler systems, alarm systems, fire doors, exit lighting), were not in proper working order at all times: A.) On or about Friday, January 15, 2016 at 184-60 Jamaica Avenue, Hollis, NY 11423 (3rd Floor) The bulbs of an emergency exit sign on the 3rd floor of the building next to the woodshop area were not functional. ABATEMENT CERTIFICATION IS REQUIRED PURSUANT TO 29 CFR 1903.19
Citation ID 01002A
Citaton Type Other
Standard Cited 19100132 D01
Issuance Date 2016-07-01
Abatement Due Date 2016-08-18
Current Penalty 0.0
Initial Penalty 2000.0
Final Order 2016-08-02
Nr Instances 1
Nr Exposed 18
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.132(d)(1): The employer did not assess the workplace to determine if hazards are present, or are likely to be present, which necessitate the use of personal protective equipment (PPE): A.) On or about Friday, January 15, 2016 at 184-60 Jamaica Avenue, Hollis, NY 11423 The employer failed to assess the workplace to determine hazards present necessitating the usage of personal protective equipment (i.e. hand protection) exposing employees to thermal hazards. ABATEMENT CERTIFICATION IS REQUIRED PURSUANT TO 29 CFR 1903.19
Citation ID 01002B
Citaton Type Other
Standard Cited 19100138 A
Issuance Date 2016-07-01
Abatement Due Date 2016-07-21
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2016-08-02
Nr Instances 1
Nr Exposed 3
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.138(a): The employer did not select and require employee(s) to use appropriate hand protection when employees' hands were exposed to hazards such as those from skin absorption of harmful substances; severe cuts or lacerations; severe abrasion; punctures; chemical burns; thermal burns; and harmful temperature extremes. A.) On or about Friday, January 15, 2016 at 184-60 Jamaica Avenue, Hollis, NY 11423 The employer failed to provide employees exposed to thermal burns during the application of clothmaterial to wooden jewelry display cases appropriate hand protection. ABATEMENT CERTIFICATION IS REQUIRED PURSUANT TO 29 CFR 1903.19
Citation ID 01003
Citaton Type Serious
Standard Cited 19100212 A03 II
Issuance Date 2016-07-01
Abatement Due Date 2016-07-08
Current Penalty 4200.0
Initial Penalty 7000.0
Final Order 2016-08-02
Nr Instances 1
Nr Exposed 3
Related Event Code (REC) Complaint
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.212(a)(3)(ii): Point(s) of operation of machinery were not guarded to prevent employee(s) from having any part of their body in the danger zone(s) during operating cycle(s): A.) On or about Wednesday, January 6, 2016 at 184-60 Jamaica Avenue, Hollis, NY 11423 The point of operation of a die-cutting machine used during the production of jewelry display cases was observed missing a guard resulting in an employee sustaining injuries to the left hand. B.) On or about Friday, January 15, 2016 at 184-60 Jamaica Avenue, Hollis, NY 11423 The point of operation of a die-cutting machine used during the production of jewelry display cases was observed missing a guard resulting in an employee sustaining injuries to the left hand. ABATEMENT CERTIFICATION IS NOT REQUIRED
Citation ID 01004
Citaton Type Serious
Standard Cited 19100213 C01
Issuance Date 2016-07-01
Abatement Due Date 2016-07-14
Current Penalty 1600.0
Initial Penalty 2800.0
Final Order 2016-08-02
Nr Instances 1
Nr Exposed 1
Related Event Code (REC) Complaint
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.213(c)(1): Circular handfed ripsaw(s) were not guarded by an automatically adjusting hood which completely enclosed that portion of the saw above the table and above the material being cut: A.) On or about Friday, January 15, 2016 at 184-60 Jamaica Avenue, Hollis, NY 11423 A table saw used by employees within the woodshop area during the manufacturing of jewelry display cases was observed unguarded exposing employees to amputation hazards. ABATEMENT CERTIFICATION IS REQUIRED PURSUANT TO 29 CFR 1903.19
Citation ID 01005A
Citaton Type Serious
Standard Cited 19100219 D01
Issuance Date 2016-07-01
Abatement Due Date 2016-08-18
Current Penalty 1200.0
Initial Penalty 2000.0
Final Order 2016-08-02
Nr Instances 1
Nr Exposed 1
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.219(d)(1): Pulley(s) with part(s) seven feet or less from the floor or work platform were not guarded in accordance with the requirements specified in 29 CFR 1910.219(m) and (o): A.) On or about Friday, January 15, 2016 at 184-60 Jamaica Avenue, Hollis, NY 11423 (Rear of Building) The vertical pulley of a compressed air tank located in the rear of the building was observed unguarded exposing employees to amputation hazards. ABATEMENT CERTIFICATION IS REQUIRED PURSUANT TO 29 CFR 1903.19
Citation ID 01005B
Citaton Type Serious
Standard Cited 19100219 E03 I
Issuance Date 2016-07-01
Abatement Due Date 2016-08-18
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2016-08-02
Nr Instances 1
Nr Exposed 1
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.219(e)(3)(i): Vertical or inclined belt(s) were not enclosed by guard(s) conforming to the requirements specified at 29 CFR 1910.219(m) and (o): A.) On or about Friday, January 15, 2016 at 184-60 Jamaica Avenue, Hollis, NY 11423 (3rd Floor) The belt of a compressed air tank located in the rear of the building was observed missing a guard exposing employees to amputation hazards. ABATEMENT CERTIFICATION IS NOT REQUIRED
Citation ID 01006
Citaton Type Serious
Standard Cited 19100242 B
Issuance Date 2016-07-01
Abatement Due Date 2016-07-28
Current Penalty 1200.0
Initial Penalty 2000.0
Final Order 2016-08-02
Nr Instances 1
Nr Exposed 18
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.242(b): Compressed air used for cleaning purposes was not reduced to less than 30 p.s.i.: A.) On or about Friday, January 15, 2016 at 184-60 Jamaica Avenue, Hollis, NY 11423 Compressed air used by employees for cleaning purpose was not reduced to less than 30 p.s.i. exposing employees to fire/explosion hazards. ABATEMENT CERTIFICATION IS REQUIRED PURSUANT TO 29 CFR 1903.19
Citation ID 02001
Citaton Type Other
Standard Cited 19040029 B03
Issuance Date 2016-07-01
Abatement Due Date 2016-07-08
Current Penalty 600.0
Initial Penalty 1000.0
Final Order 2016-08-02
Nr Instances 1
Nr Exposed 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1904.29(b)(3): Each recordable injury or illness was not entered on the OSHA 300 Log and on an incident report (OSHA Form 301or equivalent) within seven (7) calendar days of receiving information that a recordable injury or illness had occurred. A.) On or about Friday, January 6, 2016 at 184-60 Jamaica Avenue, Hollis, NY 11423 Within seven (7) calendar days the employer failed to enter a recordable work-related injury involving an employee on the OSHA 300 log for calendar year 2016. ABATEMENT CERTIFICATION IS NOT REQUIRED
Citation ID 02002
Citaton Type Other
Standard Cited 19040039 A02
Issuance Date 2016-07-01
Abatement Due Date 2016-07-08
Current Penalty 600.0
Initial Penalty 1000.0
Final Order 2016-08-02
Nr Instances 1
Nr Exposed 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1904.39(a)(2): The employer did not report an in-patient hospitalization, amputation, or loss of an eye as a result of a work-related incident to OSHA within twenty-four (24) hours. A.) On or about Friday, January 15, 2016 at 184-60 Jamaica Avenue, Hollis, NY 11423 The employer failed to report to OSHA the in-patient hospitalization of employee within twenty-four (24) hours. ABATEMENT CERTIFICATION IS NOT REQUIRED
Citation ID 02003
Citaton Type Other
Standard Cited 19100147 C07 I C
Issuance Date 2016-07-01
Abatement Due Date 2016-08-18
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2016-08-02
Nr Instances 1
Nr Exposed 18
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.147(c)(7)(i)(C): Employees whose work operations were in an area where energy control procedures were utilized were not instructed about the procedure: A.) On or about Friday, January 15, 2016 at 184-60 Jamaica Avenue, Hollis, NY 11423 The employer failed to provide instructions to employees that are required to use and/or work around equipment where energy control procedures are used. ABATEMENT CERIFICATION IS REQUIRED PURSUANT TO 29 CFR 1903.19
Citation ID 02004A
Citaton Type Other
Standard Cited 19101200 E01
Issuance Date 2016-07-01
Abatement Due Date 2016-08-18
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2016-08-02
Nr Instances 1
Nr Exposed 18
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.1200(e)(1): The employer did not develop, implement, and/or maintain at the workplace a written hazard communication program which describes how the criteria specified in 29 CFR 1910.1200(f), (g), and (h) will be met: A.) On or about Friday, January 15, 2016 at 184-60 Jamaica Avenue, Hollis, NY 11423 The employer failed to develop, implement and maintain a written hazard communication program for employees that are required to use hazardous chemicals such as but not limited too; F90 Flex Glue and R 2258 Resin Adhesive during the fabrication of jewelry display cases. WRITTEN ABATEMENT CERTIFICATION IS REQUIRED PURSUANT TO 29 CFR 1903.19
Citation ID 02004B
Citaton Type Other
Standard Cited 19101200 F05 I
Issuance Date 2016-07-01
Abatement Due Date 2016-07-21
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2016-08-02
Nr Instances 1
Nr Exposed 18
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.1200(f)(5)(i): The employer did not ensure that each container of hazardous chemicals in the workplace was labeled, tagged or marked with the identity of the hazardous chemical(s) contained therein: A.) On or about Friday, January 15, 2016 at 184-60 Jamaica Avenue, Hollis, NY 11423 The employer failed to ensure chemical containers used by employees during the manufacturing of jewelry display cases were properly labeled with the identity of the hazardous chemical. ABATEMENT CERTIFICATION IS REQUIRED PURSUANT TO 29 CFR 1903.19
Citation ID 02004C
Citaton Type Other
Standard Cited 19101200 H01
Issuance Date 2016-07-01
Abatement Due Date 2016-08-18
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2016-08-02
Nr Instances 1
Nr Exposed 18
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.1200(h)(1): Employees were not provided effective information and training on hazardous chemicals in their work area at the time of their initial assignment and whenever a new hazard that the employees had not been previously trained about was introduced into their work area: A.) On or about Friday, January 15, 2016 at 184-60 Jamaica Avenue, Hollis, NY 11423 The employer failed to provide employees that are required to use hazardous chemicals such as but not limited too; F 90 Flex Glue and R 2258 Resin Adhesive during the manufacturing of jewelry display cases effective information and training in the safe usage of hazardous chemicals. WRITTEN ABATEMENT CERTIFICATION IS REQUIRED PURSUANT TO 29 CFR 1903.19

Paycheck Protection Program

Loan Number Loan Funded Date SBA Origination Office Code Loan Delivery Method Borrower Street Address
2940907700 2020-05-01 0202 PPP 17806 104TH AVE, JAMAICA, NY, 11433
Loan Status Date 2021-08-20
Loan Status Paid in Full
Loan Maturity in Months 24
SBA Guaranty Percentage 100
Loan Approval Amount (at origination) 45130
Loan Approval Amount (current) 45130
Undisbursed Amount 0
Franchise Name -
Lender Location ID 48270
Servicing Lender Name JPMorgan Chase Bank, National Association
Servicing Lender Address 1111 Polaris Pkwy, COLUMBUS, OH, 43240-2031
Rural or Urban Indicator U
Hubzone Y
LMI N
Business Age Description Existing or more than 2 years old
Project Address JAMAICA, QUEENS, NY, 11433-1000
Project Congressional District NY-05
Number of Employees 10
NAICS code 339910
Borrower Race Unanswered
Borrower Ethnicity Unknown/NotStated
Business Type Subchapter S Corporation
Originating Lender ID 194093
Originating Lender Name JPMorgan Chase Bank, National Association
Originating Lender Address CHICAGO, IL
Gender Unanswered
Veteran Unanswered
Forgiveness Amount 45661.96
Forgiveness Paid Date 2021-07-09
7499988503 2021-03-06 0202 PPS 17806 104th Ave, Jamaica, NY, 11433-1825
Loan Status Date 2022-02-19
Loan Status Paid in Full
Loan Maturity in Months 60
SBA Guaranty Percentage 100
Loan Approval Amount (at origination) 45130
Loan Approval Amount (current) 45130
Undisbursed Amount 0
Franchise Name -
Lender Location ID 48270
Servicing Lender Name JPMorgan Chase Bank, National Association
Servicing Lender Address 1111 Polaris Pkwy, COLUMBUS, OH, 43240-2031
Rural or Urban Indicator U
Hubzone Y
LMI N
Business Age Description Existing or more than 2 years old
Project Address Jamaica, QUEENS, NY, 11433-1825
Project Congressional District NY-05
Number of Employees 10
NAICS code 339999
Borrower Race Unanswered
Borrower Ethnicity Unknown/NotStated
Business Type Subchapter S Corporation
Originating Lender ID 48270
Originating Lender Name JPMorgan Chase Bank, National Association
Originating Lender Address COLUMBUS, OH
Gender Unanswered
Veteran Unanswered
Forgiveness Amount 45493.65
Forgiveness Paid Date 2022-01-03

Date of last update: 17 Mar 2025

Sources: New York Secretary of State