Inspection Nr | Report ID | Date Opened | Site Address | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
339247819 | 0216000 | 2013-08-02 | 922 E. 223RD ST, BRONX, NY, 10467 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Citation ID | 01001 |
Citaton Type | Serious |
Standard Cited | 19260021 B02 |
Issuance Date | 2013-08-13 |
Current Penalty | 720.0 |
Initial Penalty | 1200.0 |
Final Order | 2013-09-18 |
Nr Instances | 3 |
Nr Exposed | 3 |
Gravity | 1 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.21(b)(2): The employer shall instruct each employee in the recognition and avoidance of unsafe conditions and the regulations applicable to his work environment to control or eliminate any hazards or other exposure to illness or injury: On or about 8/2/2013, 922 E. 223rd Street a) The employees were not provided safety and health training as required by the standard. |
Citation ID | 01002 |
Citaton Type | Serious |
Standard Cited | 19260100 A |
Issuance Date | 2013-08-13 |
Current Penalty | 960.0 |
Initial Penalty | 1600.0 |
Final Order | 2013-09-18 |
Nr Instances | 1 |
Nr Exposed | 1 |
Gravity | 5 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.100(a): Employees working in areas where there is a possible danger of head injury from impact, or from falling or flying objects, or from electrical shock and burns, shall be protected by protective helmets: On or about 8/2/2013, 922 E. 223rd Street a) The employee working below the scaffold was not wearing a hard hat. |
Citation ID | 01003 |
Citaton Type | Serious |
Standard Cited | 19260404 B01 I |
Issuance Date | 2013-08-13 |
Current Penalty | 720.0 |
Initial Penalty | 1200.0 |
Final Order | 2013-09-18 |
Nr Instances | 1 |
Nr Exposed | 2 |
Gravity | 1 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.404(b)(1)(i): General. The employer shall use either ground fault circuit interrupters as specified in paragraph (b)(1)(ii) of this section or an assured equipment grounding conductor program as specified in paragraph (b)(1)(iii) of this section to protect employees on construction sites. These requirements are in addition to any other requirements for equipment grounding conductors: On or about 8/2/2013, 922 E. 223rd Street a) The employees were using a Hilti chipping hammer and were not provided with a ground fault circuit interrupter. |
Citation ID | 01004 |
Citaton Type | Serious |
Standard Cited | 19260416 E01 |
Issuance Date | 2013-08-13 |
Current Penalty | 720.0 |
Initial Penalty | 1200.0 |
Final Order | 2013-09-18 |
Nr Instances | 1 |
Nr Exposed | 2 |
Gravity | 1 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.416(e)(1): Worn or frayed electric cords or cables shall not be used: On or about 8/2/2013, 922 E. 223rd Street a) The extension cord used to power the Hilti chipping hammer was frayed at both ends. |
Citation ID | 01005 |
Citaton Type | Serious |
Standard Cited | 19260451 G01 I |
Issuance Date | 2013-08-13 |
Current Penalty | 1680.0 |
Initial Penalty | 2800.0 |
Final Order | 2013-09-18 |
Nr Instances | 2 |
Nr Exposed | 2 |
Gravity | 10 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.451(g)(1)(i): Each employee on a boatswains' chair, catenary scaffold, float scaffold, needle beam scaffold, or ladder jack scaffold shall be protected by a personal fall arrest system: On or about 8/2/2013 922 E. 223rd Street a) The two employees were working on the ladder jack scaffold and were not protected from falling approximately 28' to the ground below. |
Citation ID | 01006 |
Citaton Type | Serious |
Standard Cited | 19260452 K01 |
Issuance Date | 2013-08-13 |
Current Penalty | 1680.0 |
Initial Penalty | 2800.0 |
Final Order | 2013-09-18 |
Nr Instances | 1 |
Nr Exposed | 2 |
Gravity | 10 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.452(k)(1): Platforms shall not exceed a height of 20 feet (6.1 m): On or about 8/2/2013, 922 E. 223rd Street a) The ladder jack scaffold was 28' high. |