342250396
|
0213600
|
2017-04-12
|
363 GRANT STREET, BUFFALO, NY, 14213
|
|
Inspection Type |
Planned
|
Scope |
Complete
|
Safety/Health |
Safety
|
Close Conference |
2017-04-12
|
Emphasis |
L: LOCALTARG, P: LOCALTARG
|
Case Closed |
2018-10-16
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19260501 B10 |
Issuance Date |
2017-07-06 |
Current Penalty |
1000.0 |
Initial Penalty |
1570.0 |
Final Order |
2017-07-27 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.501(b)(10): Each employee engaged in roofing activities on low-slope roofs with unprotected sides and edges 6 feet or more above lower levels, was not protected from falling by guardrail systems, safety net systems, personal fall arrest systems, or a combination of warning line system and guardrail system, warning line system and safety net system, or warning line system and personal fall arrest system, or warning line system and safety monitoring system. Or, on roofs 50-feet (15.25 m) or less in width, each employee was not protected by use of a monitoring system: a) On or about 4/12/17, at the overhang area of the site, Buffalo, NY. Employee, on the top of overhang installing foams, was not protected by fall protection system(s). NO ABATEMENT CERTIFICATION REQUIRED |
|
Citation ID |
01002 |
Citaton Type |
Serious |
Standard Cited |
19261053 B06 |
Issuance Date |
2017-07-06 |
Current Penalty |
1000.0 |
Initial Penalty |
1570.0 |
Final Order |
2017-07-27 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.1053(b)(6): Unsecured ladder(s) were used on surfaces that were not stable and level: a) On or about 4/12/17, at the overhang area of the site, Buffalo, NY. The extension ladder, that was placed on rough ground and used to access the overhang, was not secured. NO ABATEMENT CERTIFICATION REQUIRED |
|
|
335527784
|
0213600
|
2012-08-02
|
1250 AMHERST STREET, BUFFALO, NY, 14216
|
|
Inspection Type |
Planned
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2012-08-17
|
Emphasis |
L: FALL, P: FALL
|
Case Closed |
2013-06-21
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19260501 B10 |
Issuance Date |
2012-09-28 |
Current Penalty |
800.0 |
Initial Penalty |
2800.0 |
Contest Date |
2012-10-25 |
Final Order |
2013-03-27 |
Nr Instances |
2 |
Nr Exposed |
8 |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.501(b)(10): Employee(s) engaged in roofing activities on low-sope roofs, with unprotected sides and edges 6 feet (1.8m) or more above lower levels were not protected from falling by a guardrail system, safety net systems, personal fall arrest systems, or a combination of warning line system and guardrail system, warning line system and safety net system, or warning line system and personal fall arrest system, or warning line system and safety monitoring system: a) North end of Mitchell Hall at Nichols School, no fall protection was provided for the five (5) employees observed doing roofing work exposed to falls of 27 feet, 3 inches to the ground below. b) West side of Mitchell Hall at Nichols School, no fall protection was being utilized by the three (3) employees doing roofing work and were exposed to falls of 32 feet, 6 inches to the blacktop/concrete surface below. NO ABATEMENT CERTIFICATION REQUIRED |
|
Citation ID |
01002 |
Citaton Type |
Serious |
Standard Cited |
19261051 A |
Issuance Date |
2012-09-28 |
Current Penalty |
0.0 |
Initial Penalty |
2000.0 |
Contest Date |
2012-10-25 |
Final Order |
2013-03-27 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.1051(a): Stairways or ladders were not provided at all personnel points of access where there was a break in elevation of 19 inches (48 cm) or more, and no ramp, runway, sloped embankment, or personnel hoist was provided: a) West side of Mitchell Hall at Nichols School, employee observed climbing a tower of frames consisting of tubular welded frame scaffolding and no ladder was provided. The initial step from the ground to the cross member of the frame was 29 1/2 inches and it was 19 1/2 inches between each cross member on the frames of the scaffold. The employee was exposed to falls up to 32 feet, 8 inches to the blacktop/concrete below. ABATEMENT CERTIFICATION REQUIRED |
|
Citation ID |
01003A |
Citaton Type |
Serious |
Standard Cited |
19261053 B01 |
Issuance Date |
2012-09-28 |
Current Penalty |
0.0 |
Initial Penalty |
1200.0 |
Contest Date |
2012-10-25 |
Final Order |
2013-03-27 |
Nr Instances |
1 |
Nr Exposed |
5 |
Gravity |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.1053(b)(1): Portable ladders were used for access to an upper landing surface and the ladder side rails did not extend to at least 3 feet (.9m) above the upper landing surface to which the ladder was used to gain access nor was the ladder secured at it's top to a ridgid support and a grasping device, such as a grabrail, provided to assist the employee in mounting and dismounting the the ladder: a) North side of Mitchell Hall at Nichols School, extension ladder being used for access to and from the roof did not extend three (3) feet above the roof. NO ABATEMENT CERTIFICATION REQUIRED |
|
Citation ID |
01003B |
Citaton Type |
Serious |
Standard Cited |
19261053 B08 |
Issuance Date |
2012-09-28 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Contest Date |
2012-10-25 |
Final Order |
2013-03-27 |
Nr Instances |
1 |
Nr Exposed |
4 |
Gravity |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.1053(b)(8): Ladders placed in a location where they could be displaced by workplace activities or traffic, such as in passageways, doorways, or driveways, were not secured to prevent accidental displacement, nor was a barricade used to keep the activities or traffic away from the ladder: a) North side of Mitchell Hall at Nichols School, extension ladder being used for access to and from the roof to the ground was not tied-off to prevent it from being displaced. NO ABATEMENT CERTIFICATION NEEDED |
|
|
304355753
|
0213600
|
2001-04-11
|
938 GENESEE STREET, BUFFALO, NY, 14211
|
|
Inspection Type |
Prog Related
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2001-04-11
|
Emphasis |
L: FALL, S: CONSTRUCTION
|
Case Closed |
2001-04-11
|
|
106864358
|
0213600
|
1996-05-30
|
2001 MAIN STREET (CANISIUS COLLEGE), BUFFALO, NY, 14208
|
|
Inspection Type |
Unprog Rel
|
Scope |
Complete
|
Safety/Health |
Safety
|
Close Conference |
1996-09-10
|
Case Closed |
1997-03-18
|
Related Activity
Type |
Referral |
Activity Nr |
901212092 |
Safety |
Yes |
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Other |
Standard Cited |
19260501 B13 |
Issuance Date |
1996-09-13 |
Abatement Due Date |
1996-09-18 |
Initial Penalty |
1500.0 |
Contest Date |
1996-10-03 |
Final Order |
1997-03-17 |
Nr Instances |
1 |
Gravity |
10 |
|
Citation ID |
01002 |
Citaton Type |
Other |
Standard Cited |
19260556 B02 IV |
Issuance Date |
1996-09-13 |
Abatement Due Date |
1996-09-18 |
Initial Penalty |
1500.0 |
Contest Date |
1996-10-03 |
Final Order |
1997-03-17 |
Nr Instances |
1 |
Nr Exposed |
2 |
Gravity |
10 |
|
Citation ID |
01003 |
Citaton Type |
Serious |
Standard Cited |
19260556 B02 V |
Issuance Date |
1996-09-13 |
Abatement Due Date |
1996-09-18 |
Current Penalty |
1000.0 |
Initial Penalty |
1500.0 |
Contest Date |
1996-10-03 |
Final Order |
1997-03-17 |
Nr Instances |
2 |
Nr Exposed |
4 |
Gravity |
10 |
|
Citation ID |
01004 |
Citaton Type |
Other |
Standard Cited |
19261051 A |
Issuance Date |
1996-09-13 |
Abatement Due Date |
1996-09-18 |
Initial Penalty |
1500.0 |
Contest Date |
1996-10-03 |
Final Order |
1997-03-17 |
Nr Instances |
1 |
Nr Exposed |
3 |
Gravity |
10 |
|
|
114099401
|
0213600
|
1993-02-10
|
ALL SAINTS SCHOOL, 127 CHADDUCK AVENUE, BUFFALO, NY, 14207
|
|
Inspection Type |
Complaint
|
Scope |
Complete
|
Safety/Health |
Safety
|
Close Conference |
1993-02-10
|
Case Closed |
1993-07-26
|
Related Activity
Type |
Complaint |
Activity Nr |
74762865 |
Safety |
Yes |
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Repeat |
Standard Cited |
19260500 G01 |
Issuance Date |
1993-03-25 |
Abatement Due Date |
1993-03-30 |
Current Penalty |
200.0 |
Initial Penalty |
1600.0 |
Contest Date |
1993-04-16 |
Final Order |
1993-06-24 |
Nr Instances |
1 |
Nr Exposed |
4 |
Gravity |
02 |
|
|
107345340
|
0213600
|
1992-04-27
|
60 SOUTH LINCOLN AVE, ORCHARD PARK MIDDLE SCHOOL, ORCHARD PARK, NY, 14127
|
|
Inspection Type |
Unprog Rel
|
Scope |
Complete
|
Safety/Health |
Safety
|
Close Conference |
1992-04-28
|
Case Closed |
1994-09-08
|
Related Activity
Type |
Referral |
Activity Nr |
901831826 |
Safety |
Yes |
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19260152 A01 |
Issuance Date |
1992-05-20 |
Abatement Due Date |
1992-05-27 |
Current Penalty |
800.0 |
Initial Penalty |
800.0 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
02 |
|
Citation ID |
01002 |
Citaton Type |
Serious |
Standard Cited |
19260500 G05 |
Issuance Date |
1992-05-20 |
Abatement Due Date |
1992-05-25 |
Current Penalty |
1400.0 |
Initial Penalty |
1400.0 |
Nr Instances |
1 |
Nr Exposed |
3 |
Gravity |
05 |
|
Citation ID |
02001 |
Citaton Type |
Repeat |
Standard Cited |
19260500 G04 |
Issuance Date |
1992-05-20 |
Abatement Due Date |
1992-05-27 |
Current Penalty |
200.0 |
Initial Penalty |
4000.0 |
Contest Date |
1992-06-11 |
Final Order |
1993-07-26 |
Nr Instances |
1 |
Nr Exposed |
3 |
Gravity |
10 |
|
|
106884711
|
0213600
|
1991-04-23
|
300 PEARL STREET, BUFFALO, NY, 14202
|
|
Inspection Type |
Complaint
|
Scope |
Complete
|
Safety/Health |
Safety
|
Close Conference |
1991-04-24
|
Case Closed |
1992-03-19
|
Related Activity
Type |
Complaint |
Activity Nr |
72887375 |
Safety |
Yes |
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19260404 B01 I |
Issuance Date |
1991-07-16 |
Abatement Due Date |
1991-07-19 |
Current Penalty |
525.0 |
Initial Penalty |
1050.0 |
Contest Date |
1991-08-07 |
Final Order |
1991-11-06 |
Nr Instances |
1 |
Nr Exposed |
4 |
Gravity |
05 |
|
Citation ID |
01002 |
Citaton Type |
Serious |
Standard Cited |
19260404 F06 |
Issuance Date |
1991-07-16 |
Abatement Due Date |
1991-07-19 |
Current Penalty |
375.0 |
Initial Penalty |
750.0 |
Contest Date |
1991-08-07 |
Final Order |
1991-11-06 |
Nr Instances |
1 |
Nr Exposed |
4 |
Gravity |
04 |
|
Citation ID |
01003 |
Citaton Type |
Serious |
Standard Cited |
19260500 G01 |
Issuance Date |
1991-07-16 |
Abatement Due Date |
1991-07-22 |
Current Penalty |
750.0 |
Initial Penalty |
1500.0 |
Final Order |
1991-11-06 |
Nr Instances |
1 |
Nr Exposed |
8 |
Related Event Code (REC) |
Complaint |
Gravity |
10 |
|
Citation ID |
01004 |
Citaton Type |
Serious |
Standard Cited |
19260500 G06 II |
Issuance Date |
1991-07-16 |
Abatement Due Date |
1991-07-26 |
Current Penalty |
750.0 |
Initial Penalty |
1500.0 |
Final Order |
1991-11-06 |
Nr Instances |
1 |
Nr Exposed |
8 |
Gravity |
10 |
|
Citation ID |
02001 |
Citaton Type |
Other |
Standard Cited |
19260059 E01 |
Issuance Date |
1991-07-16 |
Abatement Due Date |
1991-08-05 |
Current Penalty |
150.0 |
Initial Penalty |
300.0 |
Contest Date |
1991-08-07 |
Final Order |
1991-11-06 |
Nr Instances |
1 |
Nr Exposed |
8 |
Gravity |
03 |
|
Citation ID |
02002 |
Citaton Type |
Other |
Standard Cited |
19260059 G01 |
Issuance Date |
1991-07-16 |
Abatement Due Date |
1991-08-05 |
Current Penalty |
300.0 |
Initial Penalty |
300.0 |
Contest Date |
1991-08-07 |
Final Order |
1991-11-06 |
Nr Instances |
1 |
Nr Exposed |
8 |
Gravity |
03 |
|
Citation ID |
02003 |
Citaton Type |
Other |
Standard Cited |
19260059 H |
Issuance Date |
1991-07-16 |
Abatement Due Date |
1991-08-05 |
Current Penalty |
150.0 |
Initial Penalty |
300.0 |
Contest Date |
1991-08-07 |
Final Order |
1991-11-06 |
Nr Instances |
1 |
Nr Exposed |
8 |
Gravity |
03 |
|
|