Search icon

WEAVER METAL & ROOFING, INC.

Company Details

Name: WEAVER METAL & ROOFING, INC.
Jurisdiction: New York
Legal type: DOMESTIC BUSINESS CORPORATION
Status: Active
Date of registration: 24 Feb 1989 (36 years ago)
Entity Number: 1329036
ZIP code: 14202
County: Erie
Place of Formation: New York
Address: 37 FRANKLIN STREET, SUITE 750, BUFFALO, NY, United States, 14202
Principal Address: 40 APPENHEIMER AVENUE, BUFFALO, NY, United States, 14214

Shares Details

Shares issued 200

Share Par Value 0

Type NO PAR VALUE

form 5500

Plan Name Plan Year EIN/PN Received Sponsor Total number of participants
WEAVER METAL & ROOFING INC 401(K) PLAN 2023 161343726 2024-02-12 WEAVER METAL & ROOFING, INC. 7
File View Page
Three-digit plan number (PN) 001
Effective date of plan 2010-01-01
Business code 238100
Sponsor’s telephone number 7168918844
Plan sponsor’s address 40 APPENHEIMER AVE, BUFFALO, NY, 14214

Signature of

Role Plan administrator
Date 2024-02-07
Name of individual signing PATRICK BYRNE
WEAVER METAL & ROOFING INC 401(K) PLAN 2022 161343726 2023-09-12 WEAVER METAL & ROOFING, INC. 7
File View Page
Three-digit plan number (PN) 001
Effective date of plan 2010-01-01
Business code 238100
Sponsor’s telephone number 7168918844
Plan sponsor’s address 40 APPENHEIMER AVE, BUFFALO, NY, 14214

Signature of

Role Plan administrator
Date 2023-09-12
Name of individual signing PATRICK BYRNE
WEAVER METAL & ROOFING INC 401(K) PLAN 2021 161343726 2022-02-24 WEAVER METAL & ROOFING, INC. 10
File View Page
Three-digit plan number (PN) 001
Effective date of plan 2010-01-01
Business code 238100
Sponsor’s telephone number 7168918844
Plan sponsor’s address 40 APPENHEIMER AVE, BUFFALO, NY, 14214

Signature of

Role Plan administrator
Date 2022-02-22
Name of individual signing PATRICK BYRNE
WEAVER METAL & ROOFING INC 401(K) PLAN 2020 161343726 2021-03-12 WEAVER METAL & ROOFING, INC. 10
File View Page
Three-digit plan number (PN) 001
Effective date of plan 2010-01-01
Business code 238100
Sponsor’s telephone number 7168918844
Plan sponsor’s address 40 APPENHEIMER AVE, BUFFALO, NY, 14214

Signature of

Role Plan administrator
Date 2021-03-12
Name of individual signing PATRICK BYRNE
WEAVER METAL & ROOFING INC 401(K) PLAN 2019 161343726 2020-07-08 WEAVER METAL & ROOFING, INC. 10
File View Page
Three-digit plan number (PN) 001
Effective date of plan 2010-01-01
Business code 238100
Sponsor’s telephone number 7168918844
Plan sponsor’s address 40 APPENHEIMER AVE, BUFFALO, NY, 14214

Signature of

Role Plan administrator
Date 2020-06-10
Name of individual signing PATRICK BYRNE
WEAVER METAL & ROOFING INC 401(K) PLAN 2018 161343726 2019-02-04 WEAVER METAL & ROOFING, INC. 10
File View Page
Three-digit plan number (PN) 001
Effective date of plan 2010-01-01
Business code 238100
Sponsor’s telephone number 7168918844
Plan sponsor’s address 40 APPENHEIMER AVE, BUFFALO, NY, 14214

Signature of

Role Plan administrator
Date 2019-02-04
Name of individual signing PATRICK BYRNE
WEAVER METAL & ROOFING INC 401(K) PLAN 2017 161343726 2018-03-07 WEAVER METAL & ROOFING, INC. 8
File View Page
Three-digit plan number (PN) 001
Effective date of plan 2010-01-01
Business code 238100
Sponsor’s telephone number 7168918844
Plan sponsor’s address 40 APPENHEIMER AVE, BUFFALO, NY, 14214

Signature of

Role Plan administrator
Date 2018-02-26
Name of individual signing PATRICK BYRNE
WEAVER METAL & ROOFING INC 401(K) PLAN 2016 161343726 2017-09-27 WEAVER METAL & ROOFING, INC. 10
File View Page
Three-digit plan number (PN) 001
Effective date of plan 2010-01-01
Business code 238100
Sponsor’s telephone number 7168918844
Plan sponsor’s address 40 APPENHEIMER AVE, BUFFALO, NY, 14214

Signature of

Role Plan administrator
Date 2017-09-27
Name of individual signing PATRICK BYRNE
WEAVER METAL & ROOFING INC 401(K) PLAN 2015 161343726 2016-03-19 WEAVER METAL & ROOFING, INC. 9
File View Page
Three-digit plan number (PN) 001
Effective date of plan 2010-01-01
Business code 238100
Sponsor’s telephone number 7168918844
Plan sponsor’s address 40 APPENHEIMER AVE, BUFFALO, NY, 14214

Signature of

Role Plan administrator
Date 2016-03-18
Name of individual signing ANTHONY BYRNE
WEAVER METAL & ROOFING, INC. 401(K)PLAN 2014 161343726 2015-10-07 WEAVER METAL & ROOFING, INC. 11
File View Page
Three-digit plan number (PN) 001
Effective date of plan 2010-01-01
Business code 238100
Sponsor’s telephone number 7168918844
Plan sponsor’s address 40 APPENHEIMER AVE, BUFFALO, NY, 14214

Signature of

Role Plan administrator
Date 2015-10-07
Name of individual signing ANTHONY BYRNE

Chief Executive Officer

Name Role Address
PATRICK R. BYRNE Chief Executive Officer 40 APPENHEIMER AVENUE, BUFFALO, NY, United States, 14214

DOS Process Agent

Name Role Address
LAW OFFICES OF RICHARD A. CLACK DOS Process Agent 37 FRANKLIN STREET, SUITE 750, BUFFALO, NY, United States, 14202

History

Start date End date Type Value
2025-02-06 2025-02-06 Address 40 APPENHEIMER AVENUE, BUFFALO, NY, 14214, 2902, USA (Type of address: Chief Executive Officer)
2025-02-06 2025-02-06 Address 40 APPENHEIMER AVENUE, BUFFALO, NY, 14214, USA (Type of address: Chief Executive Officer)
2024-04-23 2024-04-23 Address 40 APPENHEIMER AVENUE, BUFFALO, NY, 14214, USA (Type of address: Chief Executive Officer)
2024-04-23 2024-04-23 Address 40 APPENHEIMER AVENUE, BUFFALO, NY, 14214, 2902, USA (Type of address: Chief Executive Officer)
2024-04-23 2025-02-06 Address 37 FRANKLIN STREET, SUITE 750, BUFFALO, NY, 14202, USA (Type of address: Service of Process)
2024-04-23 2025-02-06 Shares Share type: NO PAR VALUE, Number of shares: 200, Par value: 0
2024-04-23 2025-02-06 Address 40 APPENHEIMER AVENUE, BUFFALO, NY, 14214, USA (Type of address: Chief Executive Officer)
2024-04-23 2025-02-06 Address 40 APPENHEIMER AVENUE, BUFFALO, NY, 14214, 2902, USA (Type of address: Chief Executive Officer)
2011-03-21 2024-04-23 Address 1300 MAIN PLACE TOWER, 350 MAIN STREET, BUFFALO, NY, 14202, 3713, USA (Type of address: Service of Process)
2005-03-02 2024-04-23 Address 40 APPENHEIMER AVENUE, BUFFALO, NY, 14214, 2902, USA (Type of address: Chief Executive Officer)

Filings

Filing Number Date Filed Type Effective Date
250206004209 2025-02-06 BIENNIAL STATEMENT 2025-02-06
240423003571 2024-04-23 BIENNIAL STATEMENT 2024-04-23
110321002561 2011-03-21 BIENNIAL STATEMENT 2011-02-01
090220002229 2009-02-20 BIENNIAL STATEMENT 2009-02-01
070213003016 2007-02-13 BIENNIAL STATEMENT 2007-02-01
050302003041 2005-03-02 BIENNIAL STATEMENT 2005-02-01
030204002405 2003-02-04 BIENNIAL STATEMENT 2003-02-01
010221002068 2001-02-21 BIENNIAL STATEMENT 2001-02-01
990224002493 1999-02-24 BIENNIAL STATEMENT 1999-02-01
970417002366 1997-04-17 BIENNIAL STATEMENT 1997-02-01

OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
345884373 0213600 2022-04-06 22 FLICKINGER COURT, AMHERST, NY, 14228
Inspection Type Planned
Scope Partial
Safety/Health Safety
Close Conference 2022-04-06
Emphasis L: FALL, P: FALL
Case Closed 2022-07-05

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19260501 B11
Issuance Date 2022-06-02
Current Penalty 1900.0
Initial Penalty 3143.0
Final Order 2022-06-21
Nr Instances 1
Nr Exposed 2
Gravity 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.501(b)(11):Each employee on a steep roof with unprotected sides and edges 6 feet or more above lower levels was not protected from falling by guardrail systems with toeboards, safety net systems, or personal fall arrest systems: a) On or about 4/6/2022, at the roof area of the site, Amherst, NY. Employees, engaged in roofing work of a steep roof with slopes of 5 in 12 and 7 in 12, including tear-off and new shingles, were not protected by fall protections. NO ABATEMENT CERTIFICATION REQUIRED
343363990 0213600 2018-08-06 1285 ELMWOOD AVENUE, BUFFALO, NY, 14222
Inspection Type Planned
Scope Partial
Safety/Health Safety
Close Conference 2018-08-06
Emphasis L: FALL, P: FALL
Case Closed 2019-04-23

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19260502 H01 V
Issuance Date 2018-08-16
Current Penalty 2000.0
Initial Penalty 5497.0
Contest Date 2018-09-11
Final Order 2018-12-17
Nr Instances 1
Nr Exposed 2
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.502(h)(1)(v): Safety monitor performed duties which took him away from monitoring duties.
342468766 0213600 2017-07-13 500 MARTIN ROAD, LACKAWANNA, NY, 14218
Inspection Type Prog Related
Scope Complete
Safety/Health Safety
Emphasis N: CTARGET, P: CTARGET
Case Closed 2018-03-23

Related Activity

Type Inspection
Activity Nr 1246828
Safety Yes
Type Inspection
Activity Nr 1246858
Safety Yes

Violation Items

Citation ID 01001A
Citaton Type Serious
Standard Cited 19260502 C03
Issuance Date 2017-09-25
Current Penalty 1901.0
Initial Penalty 3802.0
Contest Date 2017-10-02
Final Order 2018-03-02
Nr Instances 1
Nr Exposed 2
Gravity 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.502(c(3): The employer did not ensure affected employee's knowledge or use of fall protection systems or equipment indicated that the employee's retained the requisite understanding or skill: a) On or about 7/13/17 on roof E of the Lackawanna Middle School Building, 500 Martin Rd., Lackawanna, NY: Two employees engaged in roofing work on a flat roof were applying sealant at the roof edge around the perimeter of the roof and were protected from falling approx. 12 ft. off the west and south sides of the roof by a proper wood guardrail system consisting of horizontal wood 2 x 4 toprails, and horizontal wood 2 x 4 midrails, installed at the proper height. The toprails and midrails were nailed into vertical wood 2 x 4 posts, spaced 5 ft. on center. The employees had just completed the sealing work on the west and south sides of the roof and were working on the east side, moving north. Shortly ahead of them was a section of guardrail that had a span of approx. 14 foot where no vertical post was installed. This horizontal span of the toprails and midrails was greater than the 8 foot span between vertical posts recommended for wooden guardrails in Appendix B of Subpart M of this standard. This section was located above two dumpsters setting on the ground. There was a short steep wood ramp just beyond this section of guardrail. Employees were exposed to a potential fall of approx. 9 ft. to the bottom of the dumpster. NO ABATEMENT CERTIFICATION REQUIRED
Citation ID 01001B
Citaton Type Serious
Standard Cited 19260502 B05
Issuance Date 2017-09-25
Current Penalty 0.0
Initial Penalty 0.0
Contest Date 2017-10-02
Final Order 2018-03-02
Nr Instances 1
Nr Exposed 2
Gravity 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.502(b)(5): Midrails, screens, mesh, intermediate vertical members, solid panels, and equivalent structural members were not capable of withstanding, without failure, a force of at least 150 pounds (666 N) applied in any downward or outward di a) On or about 7/13/17 on roof E of the Lackawanna Middle School Building, 500 Martin Rd., Lackawanna, NY: Two employees engaged in roofing work on a flat roof were applying sealant at the roof edge around the perimeter of the roof and were protected from falling approx. 12 ft. off the west and south sides of the roof by a proper wood guardrail system consisting of horizontal wood 2 x 4 toprails, and horizontal wood 2 x 4 midrails, installed at the proper height. The toprails and midrails were nailed into vertical wood 2 x 4 posts, spaced 5 ft. on center. The employees had just completed the sealing work on the west and south sides of the roof and were working on the east side, moving north. Shortly ahead of them was a section of guardrail that had a span of approx. 14 foot where no vertical post was installed. This horizontal span of the toprails and midrails was greater than the 8 foot span between vertical posts recommended for wooden guardrails in Appendix B of Subpart M of this standard. This section was located above two dumpsters setting on the ground. There was a short steep wood ramp just beyond this section of guardrail. Employees were exposed to a potential fall of approx. 9 ft. to the bottom of the dumpster. NO ABATEMENT CERTIFICATION REQUIRED
338979974 0213600 2013-03-26 1255 NIAGARA FALLS BOULEVARD, AMHERST, NY, 14226
Inspection Type Planned
Scope Partial
Safety/Health Safety
Close Conference 2013-03-26
Emphasis L: FALL, P: FALL
Case Closed 2013-09-26

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19260501 B10
Issuance Date 2013-04-16
Current Penalty 750.0
Initial Penalty 2100.0
Contest Date 2013-05-07
Final Order 2013-07-31
Nr Instances 1
Nr Exposed 1
Gravity 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.501(b)(10): Each employee engaged in roofing activities on low-slope roofs with unprotected sides and edges 6 feet or more above lower levels, was not protected from falling by guardrail systems, safety net systems, personal fall arrest systems, or a combination of warning line system and guardrail system, warning line system and safety net system, or warning line system and personal fall arrest system, or warning line system and safety monitoring system. Or, on roofs 50-feet (15.25 m) or less in width, each employee was not protected by use of a monitoring system. a) On or about 3/26/13, at the loading dock area of the site, Amherst, NY. Employee, performing roofing repair work, was not protected by the above-mentioned fall protection systems. No Abatement Certification Required

Date of last update: 27 Feb 2025

Sources: New York Secretary of State